Cummins PID selections are in lists/groups - you have to select the ENTIRE group, you can't select individual PID's from the group - it's all or nothing.
This is a restriction/requirement of the Cummins ECM, unlike Duramax and other GM applications where users can select the individual PID's they wish to log.
Cheers
Cindy
You have to set up the dashboard yourself. Info is is the help, tutorial section of the software.
that kinda makes it hard to read a log when you have 96 thigs on the log...lol is there anyway to move to pid's together say if you just wanted like, boost,rpm,timing,rail pressure,main,pilot injection all together? and when I go to dashboard b on the scan tool it does nothing, I can see everything working good on the regular screen just when I swith to dashboard b nothing works, the tach is at 0 same as every other gauge. sorry for so many questions, thanks Danny
If you were logging 96 different things the frame rate would be very slow.
The design of the Cummins ECM is the limiting factor here. You either log everything in the group, or nothing in the group. You will need to determine which groups are important to get good frame rates.
I guess this issue is probably the single biggest reason why there are not many data logging products available.
Cheers
Cindy